Potential Gradient

Name
PG
Date from
!Please note that if no Date to: appears below, the measurements are ongoing!
Time resolution
1 Minute
Instrument manufacturer
Rotating dipole electric field mill
Data type
in-situ
Location of measured variable
ground
Other info

Rotating dipole field mill. The field mill’s frequency bandwidth is from 0 to 10 Hz, sensitivity 2 V/m, amplitude range ± 1500 V/m, and the output
voltage of ±3.5 V. The system requires 12 V buffer power supply. The field mills are mounted on steel support towers with a boom 2.5 m above the surface.